Pressure Reducing Valve with Off-Peak Flows Bypass BC-420-2B-P

Hydraulically operated, pressure reducing control valve that reduces higher upstream pressure to lower constant downstream pressure, regardless of fluctuating demand or varying upstream pressure. the model includes an off peak flows by-pass regulated with a Direct Acting Pressure Reducing valve mounted on the valve body. BERMAD 400 series valves are hydraulically operated, simple and reliable, globe valves with full bore hydrodynamic body providing an unobstructed flow path and superior performance. The valves balanced rolling-diaphragm assembly is vulcanized with a rugged radial seal disk construction, performing as the valves only moving part.

Product Features & Benefits
  • High quality construction materials ensure reliable, long lasting operation
  • Full bore valve port area and hydrodynamic body ensure unobstructed flow path; minimal pressure loss with low cavitation damage
  • Fully supported and balanced rolling diaphragm – low actuation pressure and excellent low flow regulation performance
  • Ensured operation after long standby periods
  • Straightforward three major components design – easy and simple on-site inline maintenance with minimal down time
  • 2-way pilot and control loop that continuously sense downstream pressure and immediately control the valve accordingly, providing stable, reliable and accurate pressure modulation under a wide range of flow-rate and pressure conditions
  • Line Pressure Driven – Independent operation, no external power needed
  • On-site adjustable pilot allows simple and easy calibration of required pressure level
  • Iֺֺntegrated by-pass – stability in wide range of flows
Typical Product Applications
  • Pressure control of potable water supply lines in building operating under moderate conditions
  • Excessive pressure protection of low-grade plastic supply lines in buildings
  • Protection of main supply lines of high-rise buildings where the building’s lower zones are exposed to excessive pressure
  • In parallel, redundant and duty cycled branches where uninterrupted water supply systems are required
  • When a single valve needs to service a wide range of flows

Note: Outlet pressure range 1-6 bar; 15-90 psi.